Developments, news and strategies for drug development specific to phase I through Phase III global clinical trial management, execution, project management and outsourcing. Go→
News, articles and issues specific to clinical trial practice and implementation at the investigative site level. Go→
News, developments and strategies related to eClinical, data management, data collection, ePRO, and more information technology used in the drug development chain. Go→
News, articles and issues specific to laboratories role in the clinical trial, including ECG, imaging, genotyping, tissue samples and more. Go→
News, developments and strategies for clinical trials conduct in relation to the FDA, EMEA and other global regulatory authorities overseeing the drug development industry. Go→
News, articles and strategies related to clinical trial design which impact postmarketing studies, therapeutic areas, adaptive trials, statistics, protocols and more. Go→
|
|
Animas' Development of a First-Generation Closed Loop Insulin Delivery System Progresses With Data Presented at the Advanced Technologies & Treatments for Diabetes (ATTD) Conference
Publish date: Feb 28, 2013
![]()
PR Newswire WEST CHESTER, Pa., Feb. 28, 2013
WEST CHESTER, Pa., Feb. 28, 2013 /PRNewswire/ -- Animas Corporation
announced today positive results from the second phase of human clinical trials of a first-generation, closed-loop insulin
delivery system in development, designed to predict a rise or fall in blood glucose and correspondingly increase, decrease,
suspend and resume insulin delivery. The data were presented at the Advanced Technologies & Treatments for Diabetes (ATTD)
Conference in Paris, France. The feasibility study of the predictive Hypoglycemia-Hyperglycemia Minimizer (HHM) System* in development was conducted
in 20 adults with Type 1 diabetes and designed to investigate the System's ability to adjust insulin dosing to proactively
mitigate hypoglycemia and hyperglycemia. The study, which was the first conducted in humans to investigate the configuration
of the predictive algorithm, revealed differences in the algorithm's insulin-dosing characteristics and provided insights
into the sensitivity of the System. The results also indicated that the System reduced insulin delivery in advance of hypoglycemia
and triggered timely warnings. The study was conducted by Animas Corporation in partnership with leading academic research
institutions, including the University of California, Santa Barbara; Sansum Diabetes Research
Institute; and the Center for Diabetes Technology at the University of Virginia. "We are encouraged by these results, which strengthen our understanding of the complex algorithms required of a closed-loop
insulin delivery system and further our confidence in this technology platform," said Ramakrishna
Venugopalan, Director, Research & Development at Animas Corporation. "The scope of this study also reflects
our commitment to create innovative and robust solutions for people living with diabetes." Animas began collaborating with industry, academia and advocacy organizations, including the JDRF (formerly the Juvenile
Diabetes Research Foundation), in 2010. After receiving Investigational Device Exemption (IDE) approval from the U.S. Food
and Drug Administration (FDA) in 2011, researchers began the first human clinical feasibility studies for the development
of a closed-loop insulin delivery system. Together with these key partners, Animas continues to work toward developing such
an automated system to help people living with Type 1 diabetes better control their disease. "We are encouraged by the results and progress Animas has made in the first stage of development of a closed-loop insulin
delivery system," said Aaron Kowalski, Ph.D., Vice President of Treatment Therapies Research
at JDRF. "A predictive system that cannot only detect, but can predict blood sugar levels and make automatic adjustments
to insulin delivery would be a major advance for people with Type 1 diabetes." * The HHM System includes a continuous subcutaneous insulin infusion pump, a continuous glucose monitor (CGM) and a control
algorithm used to predict changes in blood glucose.
About the Clinical Study The study also investigated the predictive, proactive methods by which the System mitigates hypoglycemia, especially as
compared to reactive, threshold-based systems. In particular, two predictive hypoglycemia safeguards of the System were investigated:
its ability to decrease/suspend insulin delivery before a hypoglycemic threshold is reached, and its ability to trigger timely
alerts for imminent hypoglycemia. The results indicated that the System reduced insulin delivery in advance of breaches of
a hypoglycemic threshold and triggered timely warnings for imminent hypoglycemia. Regarding general glucose control, the System demonstrated promising results, keeping glucose levels at an average of 133
mg/dL for the entire cohort. On average, 82.8 percent of the closed-loop time was spent at glucose levels between 70-180 mg/dL,
and little time (3.4 percent) was spent at levels below 70 mg/dL. There were no safety concerns, including diabetic ketoacidosis
or severe hypoglycemia.
About Animas Corporation SOURCE Animas Corporation
|
|